Install automatic frog polarity switching for Peco Electrofrog turnouts using frog juicers.
Cut the jumper wires under the Electrofrog turnout that connect frog to stock rails
Connect track bus feeders to the stock rails as normal
Connect the frog juicer input to your track bus (both rails)
Run a wire from the frog juicer output to the frog
Test by rolling a locomotive slowly through - no shorts should occur
Always disconnect power before working on wiring. Double-check all connections before applying power. When in doubt, use a multimeter to verify your work.